Assessment Year | 2003 |
---|---|
Principal Product | 3-Tab Shingles, Shingle Rolls |
NAICS | 324122: Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952: Asphalt Felts and Coatings |
Sales Range | $50 M to 100M |
# of Employees | 80 |
Plant Area |
284,000
ft2
|
Annual Production | 65,000,000
lb
|
Production Hrs. Annual | 6,480
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $154,677 | 4,691,333 |
kWh
|
$0.033 |
Electricity Demand | $102,670 | 7,310 |
kW-mo/yr
|
$14.05 |
Electricity Fees | $35,583 | - |
|
- |
Natural Gas | $151,063 | 34,726 |
MMBtu
|
$4.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $41,500 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,555 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $694 | $1,859 |
$425
10,371
kWh
|
$269
-
kW-mo/yr
|
- | - | - | |
02 | 2.1113: Reduce combustion air flow to optimum | $3,861 | $2,640 | - | - |
$3,861
-
MMBtu
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,440 | $26,755 |
$12,978
316,522
kWh
|
$8,230
-
kW-mo/yr
|
- | $(-587.0) | $(-181.0) | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,505 | $31,380 |
$9,670
235,870
kWh
|
$7,797
-
kW-mo/yr
|
- | $(-559.0) | $(-403.0) | |
TOTAL RECOMMENDED | $41,500 | $62,634 |
$23,073
562,763
kWh
|
$16,296
-
kW-mo/yr
|
$3,861
-
MMBtu
|
$(-1,146.0) | $(-584.0) | ||
TOTAL IMPLEMENTED | $4,555 | $4,499 |
$425
10,371
kWh
|
$269
-
kW-mo/yr
|
$3,861
-
MMBtu
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs