Assessment Year | 1988 |
---|---|
Principal Product | WOOD PICTURE FRAME MOLDS |
NAICS |
n/a
|
SIC | 2499: Wood Products, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 165 |
Plant Area |
n/a
|
Annual Production | 9,000
thousand feet
|
Production Hrs. Annual | 2,550
hrs
|
Location (State) | North Carolina |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $182,256 | 2,988,277 |
kWh
|
$0.061 |
LPG | $1,874 | 211 |
MMBtu
|
$8.88 |
Wood | $39,560 | 39,560 |
MMBtu
|
$1.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,603 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,603 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $1,298 | - |
$1,298
-
kWh
|
|
02 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,260 | - |
$1,260
20,516
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,900 | $1,041 |
$1,900
31,067
kWh
|
|
04 | 2.4133: Use most efficient type of electric motors | $795 | $799 |
$795
17,878
kWh
|
|
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,653 | - |
$1,653
26,964
kWh
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $697 | $600 |
$697
11,430
kWh
|
|
TOTAL RECOMMENDED | $7,603 | $2,440 |
$7,603
107,855
kWh
|
||
TOTAL IMPLEMENTED | $7,603 | $2,440 |
$7,603
107,855
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs