Assessment Year | 2002 |
---|---|
Principal Product | Folding Cartons |
NAICS |
n/a
|
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $50 M to 100M |
# of Employees | 186 |
Plant Area |
220,000
ft2
|
Annual Production | 40,000,000
ton
|
Production Hrs. Annual | 6,624
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $432,128 | 8,293,446 |
kWh
|
$0.052 |
Electricity Demand | $64,522 | 17,973 |
kW-mo/yr
|
$3.59 |
Electricity Fees | $35,216 | - |
|
- |
Natural Gas | $160,587 | 21,502 |
MMBtu
|
$7.47 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $156,424 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $38,048 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,772 | $18,245 |
$3,506
62,593
kWh
|
$411
-
kW-mo/yr
|
- | $98 | - | $757 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,230 | $1,440 |
$179
3,188
kWh
|
$16
-
kW-mo/yr
|
- | $623 | - | $412 | |
03 | 2.7135: Install occupancy sensors | $569 | $1,827 |
$532
9,497
kWh
|
$37
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.6218: Turn off equipment when not in use | $2,577 | $10,720 |
$2,309
41,242
kWh
|
$268
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,918 | $5,000 |
$7,094
126,699
kWh
|
$824
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.2437: Recover waste heat from equipment | $9,358 | $8,500 | - | - |
$9,358
-
MMBtu
|
- | - | - | |
07 | 4.322: Eliminate old stock and modify inventory control | $16,000 | $8,000 | - | - | - | - | $16,000 | - | |
08 | 4.522: Modify storage space to avoid rental of a warehouse | $114,000 | $335,000 | - | - | - | - | $114,000 | - | |
TOTAL RECOMMENDED | $156,424 | $388,732 |
$13,620
243,219
kWh
|
$1,556
-
kW-mo/yr
|
$9,358
-
MMBtu
|
$721 | $130,000 | $1,169 | ||
TOTAL IMPLEMENTED | $38,048 | $39,745 |
$10,600
189,292
kWh
|
$1,235
-
kW-mo/yr
|
$9,358
-
MMBtu
|
$98 | $16,000 | $757 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs