| Assessment Year | 2002 |
|---|---|
| Principal Product | Printed Circuit Board Electroplating and Polishing |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $1 M to 5M |
| # of Employees | 10 |
| Plant Area |
10,000
ft2
|
| Annual Production | 2,550
pieces
|
| Production Hrs. Annual | 2,168
hrs
|
| Location (State) | Illinois |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $5,348 | 125,933 |
kWh
|
$0.042 |
| Electricity Demand | $6,329 | 518 |
kW-mo/yr
|
$12.22 |
| Electricity Fees | $2,194 | - |
|
- |
| Natural Gas | $12,260 | 1,558 |
MMBtu
|
$7.87 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $1,345 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $472 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $873 | $3,949 |
$327
6,677
kWh
|
$451
-
kW-mo/yr
|
- | $17 | $78 | |
| 02 | 2.1133: Adjust burners for efficient operation | $472 | $440 | - | - |
$472
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $1,345 | $4,389 |
$327
6,677
kWh
|
$451
-
kW-mo/yr
|
$472
-
MMBtu
|
$17 | $78 | ||
| TOTAL IMPLEMENTED | $472 | $440 | - | - |
$472
-
MMBtu
|
- | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs