Assessment Year | 2013 |
---|---|
Principal Product | Fabricated Steel |
NAICS | 332312: Fabricated Structural Metal Manufacturing |
SIC | 3441: Fabricated Structural Metal |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
72,000
ft2
|
Annual Production | 4,000
ton
|
Production Hrs. Annual | 2,120
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $13,074 | 354,322 |
kWh
|
$0.037 |
Electricity Demand | $35,884 | 2,871 |
kW-mo/yr
|
$12.50 |
Electricity Fees | $2,276 | - |
|
- |
Natural Gas | $11,534 | 1,611 |
MMBtu
|
$7.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,896 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,062 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,687 | $4,550 | - | - | $3,687 | |
02 | 2.6231: Utilize controls to operate equipment only when needed | $1,147 | $3,500 |
$395
10,600
kWh
|
$752
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,410 | $950 |
$1,207
32,355
kWh
|
$2,203
-
kW-mo/yr
|
- | |
04 | 2.4133: Use most efficient type of electric motors | $466 | $1,291 |
$165
4,428
kWh
|
$301
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $186 | $35 |
$66
1,768
kWh
|
$120
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $8,896 | $10,326 |
$1,833
49,151
kWh
|
$3,376
-
kW-mo/yr
|
$3,687 | ||
TOTAL IMPLEMENTED | $4,062 | $2,276 |
$1,438
38,551
kWh
|
$2,624
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs