Assessment Year | 2013 |
---|---|
Principal Product | Illuminated Signs |
NAICS | 339950: Sign Manufacturing |
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 105 |
Plant Area |
77,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,210
hrs
|
Location (State) | South Dakota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $25,163 | 644,950 |
kWh
|
$0.039 |
Electricity Demand | $43,427 | 3,949 |
kW-mo/yr
|
$11.00 |
Natural Gas | $26,288 | 3,947 |
MMBtu
|
$6.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,979 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,654 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.7141: Lower light fixtures in high ceiling areas | $2,917 | $9,898 |
$1,691
28,509
kWh
|
$1,226
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $901 | $525 |
$901
18,660
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $753 | $660 |
$248
7,716
kWh
|
$505
-
kW-mo/yr
|
- | |
04 | 2.3212: Optimize plant power factor | $5,092 | $3,443 | - | - | $5,092 | |
05 | 2.3212: Optimize plant power factor | $6,316 | $3,693 | - | - | $6,316 | |
TOTAL RECOMMENDED | $15,979 | $18,219 |
$2,840
54,885
kWh
|
$1,731
-
kW-mo/yr
|
$11,408 | ||
TOTAL IMPLEMENTED | $1,654 | $1,185 |
$1,149
26,376
kWh
|
$505
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs