Assessment Year | 2013 |
---|---|
Principal Product | Frozen Pasta |
NAICS | 311824: Dry Pasta, Dough, and Flour Mixes Manufacturing from Purchased Flour |
SIC | 2098: Macaroni, Spaghetti, Vermicelli, and Noodles |
Sales Range | $10 M to 50M |
# of Employees | 180 |
Plant Area |
100,000
ft2
|
Annual Production | 65,000,000
lb
|
Production Hrs. Annual | 7,976
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $309,628 | 10,486,390 |
kWh
|
$0.030 |
Electricity Demand | $126,459 | 27,997 |
kW-mo/yr
|
$4.52 |
Natural Gas | $296,873 | 72,135 |
MMBtu
|
$4.12 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,711 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,088 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,154 | $13,790 |
$2,564
86,939
kWh
|
$590
-
kW-mo/yr
|
- | |
02 | 2.7135: Install occupancy sensors | $189 | $612 |
$189
6,391
kWh
|
- | - | |
03 | 2.4322: Use or replace with energy efficient substitutes | $1,071 | $741 |
$871
29,511
kWh
|
$200
-
kW-mo/yr
|
- | |
04 | 2.1213: Direct warmest air to combustion intake | $623 | $350 | - | - |
$623
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $853 | $500 |
$853
28,913
kWh
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $106 | $35 |
$106
3,589
kWh
|
- | - | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $2,715 | $11,000 | - | - |
$2,715
-
MMBtu
|
|
TOTAL RECOMMENDED | $8,711 | $27,028 |
$4,583
155,343
kWh
|
$790
-
kW-mo/yr
|
$3,338
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,088 | $26,678 |
$4,583
155,343
kWh
|
$790
-
kW-mo/yr
|
$2,715
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs