Assessment Year 2012
Principal Product Agricultural Equipment
NAICS 333111: Farm Machinery and Equipment Manufacturing
SIC 3523: Farm Machinery and Equipment
Sales Range $10
M
to 50
M
# of Employees 300
Plant Area 250,000
ft2
Annual Production 12,500,000
lb
Production Hrs. Annual 4,000
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $142,170 4,151,496
kWh
Electricity Demand $40,455 13,100
kW-mo/yr
Natural Gas $86,848 18,418
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $33,627 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,119

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $17,612 $72,410 $13,856
405,200
kWh
$3,756
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $7,511 $19,201 $5,910
172,800
kWh
$1,601
-
kW-mo/yr
03 2.7135: Install occupancy sensors $3,110 $6,400 $3,110
90,961
kWh
-
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $856 $331 $760
22,102
kWh
$96
-
kW-mo/yr
05 2.4239: Eliminate or reduce compressed air usage $398 $250 $398
11,641
kWh
-
06 2.4239: Eliminate or reduce compressed air usage $2,490 $6,000 $2,490
72,768
kWh
-
07 2.4231: Reduce the pressure of compressed air to the minimum required $1,650 $35 $1,465
42,840
kWh
$185
-
kW-mo/yr
TOTAL RECOMMENDED $33,627 $104,627 $27,989
818,312
kWh
$5,638
-
kW-mo/yr
TOTAL IMPLEMENTED $30,119 $97,977 $24,481
715,710
kWh
$5,638
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs