Assessment Year | 2012 |
---|---|
Principal Product | Boat Trailers |
NAICS | 336214: Travel Trailer and Camper Manufacturing |
SIC | 3732: Boat Building and Repairing |
Sales Range | $10 M to 50M |
# of Employees | 241 |
Plant Area |
300,000
ft2
|
Annual Production | 280,000
pieces
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $173,981 | 5,202,511 |
kWh
|
$0.033 |
Electricity Demand | $47,047 | 14,030 |
kW-mo/yr
|
$3.35 |
Natural Gas | $172,074 | 31,802 |
MMBtu
|
$5.41 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $43,570 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $24,752 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $24,752 | $52,500 |
$24,323
726,058
kWh
|
$429
-
kW-mo/yr
|
- | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $8,202 | $609 |
$8,036
239,890
kWh
|
$166
-
kW-mo/yr
|
- | |
03 | 2.7135: Install occupancy sensors | $436 | $719 |
$436
13,064
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,175 | $5,087 |
$2,759
82,368
kWh
|
$1,416
-
kW-mo/yr
|
- | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,536 | $18 | - | - |
$1,536
-
MMBtu
|
|
06 | 2.4239: Eliminate or reduce compressed air usage | $1,869 | $206 |
$1,652
49,327
kWh
|
$217
-
kW-mo/yr
|
- | |
07 | 2.2437: Recover waste heat from equipment | $1,407 | $630 | - | - |
$1,407
-
MMBtu
|
|
08 | 2.6218: Turn off equipment when not in use | $431 | $153 |
$431
12,870
kWh
|
- | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $762 | $3,574 |
$622
18,573
kWh
|
$140
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $43,570 | $63,496 |
$38,259
1,142,150
kWh
|
$2,368
-
kW-mo/yr
|
$2,943
-
MMBtu
|
||
TOTAL IMPLEMENTED | $24,752 | $52,500 |
$24,323
726,058
kWh
|
$429
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs