Assessment Year 2010
Principal Product Pure Gypsum and Limestone
NAICS 327410: Lime Manufacturing
SIC 3274: Lime
Sales Range $10
M
to 50
M
# of Employees 36
Plant Area 35,000
ft2
Annual Production 100,000
ton
Production Hrs. Annual 6,240
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $264,279 6,070,003
kWh
Electricity Demand $170,222 12,900
kW-mo/yr
Natural Gas $791,141 146,968
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $32,874 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $29,090

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $12,544 $16,376 $7,632
174,626
kWh
$4,912
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,332 $3,835 $1,420
32,485
kWh
$912
-
kW-mo/yr
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,800 $1,799 $1,049
23,972
kWh
$1,751
-
kW-mo/yr
04 2.7135: Install occupancy sensors $385 $717 $385
8,799
kWh
-
05 2.4231: Reduce the pressure of compressed air to the minimum required $657 $50 $437
10,008
kWh
$220
-
kW-mo/yr
06 2.4231: Reduce the pressure of compressed air to the minimum required $565 $50 $358
8,175
kWh
$207
-
kW-mo/yr
07 2.4133: Use most efficient type of electric motors $1,067 $2,774 $710
16,236
kWh
$357
-
kW-mo/yr
08 2.4111: Utilize energy-efficient belts and other improved mechanisms $12,524 - $8,338
190,800
kWh
$4,186
-
kW-mo/yr
TOTAL RECOMMENDED $32,874 $25,601 $20,329
465,101
kWh
$12,545
-
kW-mo/yr
TOTAL IMPLEMENTED $29,090 $18,275 $17,814
407,581
kWh
$11,276
-
kW-mo/yr
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs