Assessment Year | 2010 |
---|---|
Principal Product | Fasteners |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3069: Fabricated Rubber Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 129 |
Plant Area |
150,000
ft2
|
Annual Production | 11,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Minnesota |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $301,496 | 6,908,725 |
kWh
|
$0.044 |
Electricity Demand | $180,804 | 13,908 |
kW-mo/yr
|
$13.00 |
Natural Gas | $139,741 | 21,020 |
MMBtu
|
$6.65 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $60,539 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $52,993 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $745 | $487 |
$511
11,650
kWh
|
$234
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,514 | $13,439 |
$12,460
283,824
kWh
|
$5,054
-
kW-mo/yr
|
- | |
03 | 2.4239: Eliminate or reduce compressed air usage | $2,599 | $1,140 |
$1,398
31,841
kWh
|
$1,201
-
kW-mo/yr
|
- | |
04 | 2.7314: Reduce ventilation air | $3,072 | $2,000 |
$3,072
69,989
kWh
|
- | - | |
05 | 2.2692: Use outside cold water source as a supply of cooling water | $6,801 | $42,100 |
$6,801
154,926
kWh
|
- | - | |
06 | 2.1224: Replace boiler | $29,283 | $53,900 |
$2,621
59,702
kWh
|
- |
$26,662
-
MMBtu
|
|
07 | 2.2191: Substitute hot process fluids for steam | $525 | $5,000 |
$(-1,902.0)
(-43,222)
kWh
|
- |
$2,427
-
MMBtu
|
|
TOTAL RECOMMENDED | $60,539 | $118,066 |
$24,961
568,710
kWh
|
$6,489
-
kW-mo/yr
|
$29,089
-
MMBtu
|
||
TOTAL IMPLEMENTED | $52,993 | $75,479 |
$17,649
402,134
kWh
|
$6,255
-
kW-mo/yr
|
$29,089
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs