ITAC Assessment: IA0433
ITAC logo
ITAC Assessment: IA0433
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2008
Principal Product Fan Clutch for Class 8 Trucks
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $50
M
to 100
M
# of Employees 160
Plant Area 120,000
ft2
Annual Production 250,000
pieces
Production Hrs. Annual 5,980
hrs
Location (State) South Dakota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $197,738 4,968,000
kWh
Electricity Demand $5,354 1,071
kW-mo/yr
Electricity Fees $10,903 -
LPG $142,654 5,811
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $108,947 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $15,034

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
01 2.1321: Replace fossil fuel equipment with electrical equipment $52,036 - - - - $52,036
-
MMBtu
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $4,622 $459 $3,689
92,693
kWh
$933
-
kW-mo/yr
- -
03 2.4221: Install compressor air intakes in coolest locations $1,886 $832 $1,495
37,589
kWh
$391
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $1,195 $54 $955
24,006
kWh
$240
-
kW-mo/yr
- -
05 2.2437: Recover waste heat from equipment $13,871 $1,700 - - - $13,871
-
MMBtu
06 2.7142: Utilize higher efficiency lamps and/or ballasts $20,324 $37,346 $16,232
407,836
kWh
$4,092
-
kW-mo/yr
- -
07 2.7241: Install outside air damper / economizer on hvac unit $3,364 $4,000 $3,364
84,529
kWh
- - -
08 2.7224: Reduce space conditioning during non-working hours $587 $142 - - $587
-
MMBtu
-
09 2.7491: Insulate glazing, walls, ceilings, and roofs $7,158 $4,624 - - - $7,158
-
MMBtu
10 2.2511: Insulate bare equipment $524 $254 $524
13,176
kWh
- - -
11 2.6122: Adjust vents to minimize energy use $3,380 $294 - - - $3,380
-
MMBtu
TOTAL RECOMMENDED $108,947 $49,705 $26,259
659,829
kWh
$5,656
-
kW-mo/yr
$587
-
MMBtu
$76,445
-
MMBtu
TOTAL IMPLEMENTED $15,034 $5,781 $9,503
238,817
kWh
$1,564
-
kW-mo/yr
$587
-
MMBtu
$3,380
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings LPG Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs