| Assessment Year | 2008 |
|---|---|
| Principal Product | Cabmate |
| NAICS | 336330: Motor Vehicle Steering and Suspension Components (except Spring) Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 140 |
| Plant Area |
100,000
ft2
|
| Annual Production | 187,800
pieces
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $95,999 | 2,974,368 |
kWh
|
$0.032 |
| Electricity Demand | $60,130 | 668 |
kW-mo/yr
|
$90.01 |
| Electricity Fees | $480 | - |
|
- |
| Natural Gas | $89,979 | 8,999 |
MMBtu
|
$10.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,023 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,418 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2511: Insulate bare equipment | $456 | $252 | - | - |
$456
-
MMBtu
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $228 | $244 |
$156
4,840
kWh
|
$72
-
kW-mo/yr
|
- | |
| 03 | 2.7135: Install occupancy sensors | $845 | $770 |
$845
26,152
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,939 | $20,513 |
$6,645
205,700
kWh
|
$3,294
-
kW-mo/yr
|
- | |
| 05 | 2.4221: Install compressor air intakes in coolest locations | $605 | $252 |
$410
12,695
kWh
|
$195
-
kW-mo/yr
|
- | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,589 | $24 |
$1,085
33,600
kWh
|
$504
-
kW-mo/yr
|
- | |
| 07 | 2.2135: Repair and eliminate steam leaks | $2,001 | $788 |
$1,366
42,298
kWh
|
$635
-
kW-mo/yr
|
- | |
| 08 | 2.2437: Recover waste heat from equipment | $4,360 | $1,100 | - | - |
$4,360
-
MMBtu
|
|
| TOTAL RECOMMENDED | $20,023 | $23,943 |
$10,507
325,285
kWh
|
$4,700
-
kW-mo/yr
|
$4,816
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $19,418 | $23,691 |
$10,097
312,590
kWh
|
$4,505
-
kW-mo/yr
|
$4,816
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs