Assessment Year | 2006 |
---|---|
Principal Product | Tool Storage Units |
NAICS | 332439: Other Metal Container Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $50 M to 100M |
# of Employees | 355 |
Plant Area |
500,000
ft2
|
Annual Production | 25,000,000
lb
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $584,895 | 16,207,100 |
kWh
|
$0.036 |
Electricity Demand | $149,089 | 33,060 |
kW-mo/yr
|
$4.51 |
Electricity Fees | $10,004 | - |
|
- |
Natural Gas | $1,050,841 | 108,408 |
MMBtu
|
$9.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $21,659 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,196 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,347 | $11,263 |
$1,683
57,260
kWh
|
$1,664
-
kW-mo/yr
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,322 | $27,832 |
$5,374
182,800
kWh
|
$3,948
-
kW-mo/yr
|
|
03 | 2.4133: Use most efficient type of electric motors | $751 | - |
$433
14,712
kWh
|
$318
-
kW-mo/yr
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,776 | $672 |
$2,176
74,080
kWh
|
$1,600
-
kW-mo/yr
|
|
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,463 | $9,500 |
$2,573
87,520
kWh
|
$1,890
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $21,659 | $49,267 |
$12,239
416,372
kWh
|
$9,420
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $17,196 | $39,767 |
$9,666
328,852
kWh
|
$7,530
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs