Assessment Year | 2006 |
---|---|
Principal Product | Plastic Storage Containers |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 135 |
Plant Area |
75,800
ft2
|
Annual Production | 23,000,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $374,940 | 12,376,224 |
kWh
|
$0.030 |
Electricity Demand | $284,391 | 1,750 |
kW-mo/yr
|
$162.51 |
Natural Gas | $13,131 | 1,324 |
MMBtu
|
$9.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,424 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $872 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,330 | $15 |
$852
28,032
kWh
|
$478
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $872 | $280 |
$314
18,342
kWh
|
$558
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $625 | $904 |
$340
11,190
kWh
|
$285
-
kW-mo/yr
|
- | |
04 | 2.7135: Install occupancy sensors | $694 | $1,232 |
$694
22,844
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,140 | $9,328 |
$3,671
120,757
kWh
|
$2,469
-
kW-mo/yr
|
- | |
06 | 2.4133: Use most efficient type of electric motors | $1,794 | $1,566 |
$1,147
25,195
kWh
|
$647
-
kW-mo/yr
|
- | |
07 | 2.2628: Utilize a less expensive cooling method | $19,541 | $27,500 |
$14,015
461,010
kWh
|
$5,526
-
kW-mo/yr
|
- | |
08 | 2.7243: Improve air circulation with destratification fans / other methods | $428 | $1,600 | - | - |
$428
-
MMBtu
|
|
TOTAL RECOMMENDED | $31,424 | $42,425 |
$21,033
687,370
kWh
|
$9,963
-
kW-mo/yr
|
$428
-
MMBtu
|
||
TOTAL IMPLEMENTED | $872 | $280 |
$314
18,342
kWh
|
$558
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs