Assessment Year | 2005 |
---|---|
Principal Product | ham, sausage, bacon |
NAICS | 311612: Meat Processed from Carcasses |
SIC | 2013: Sausages and Other Prepared Meat Products |
Sales Range | $5 M to 10M |
# of Employees | 94 |
Plant Area |
70,000
ft2
|
Annual Production | 5,800,000
lb
|
Production Hrs. Annual | 2,959
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,878 | 2,163,657 |
kWh
|
$0.049 |
Electricity Demand | $29,400 | 5,424 |
kW-mo/yr
|
$5.42 |
Electricity Fees | $1,581 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $54,783 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,283 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $336 | $25 |
$232
4,374
kWh
|
$104
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $685 | $215 |
$471
9,617
kWh
|
$214
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.4133: Use most efficient type of electric motors | $262 | $879 |
$213
4,343
kWh
|
$49
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,513 | $8,142 |
$2,801
56,975
kWh
|
$712
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,037 | $1,906 |
$2,432
49,999
kWh
|
$605
-
kW-mo/yr
|
- | - | - | - | |
06 | 3.4111: Use closed cycle process to minimize waste water production | $11,632 | $4,000 | - | - | - |
$7,368
-
Tgal
|
- |
$4,264
-
Tgal
|
|
07 | 3.4154: Eliminate leaks in water lines and valves | $298 | $650 | - | - | - |
$189
-
Tgal
|
- |
$109
-
Tgal
|
|
08 | 2.4322: Use or replace with energy efficient substitutes | $35,020 | $29,000 | - | - |
$5,430
-
MMBtu
|
- | $29,590 | - | |
TOTAL RECOMMENDED | $54,783 | $44,817 |
$6,149
125,308
kWh
|
$1,684
-
kW-mo/yr
|
$5,430
-
MMBtu
|
$7,557
-
Tgal
|
$29,590 |
$4,373
-
Tgal
|
||
TOTAL IMPLEMENTED | $1,283 | $1,119 |
$916
18,334
kWh
|
$367
-
kW-mo/yr
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs