ITAC Assessment: IA0339
ITAC logo
ITAC Assessment: IA0339
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2004
Principal Product Soft drinks in bottles and cans
NAICS 312111: Soft Drink Manufacturing
SIC 2086: Bottled and Canned Soft Drinks and Carbonated Waters
Sales Range $50
M
to 100
M
# of Employees 120
Plant Area 258,000
ft2
Annual Production 30,000,000
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Minnesota

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $217,460 9,518,400
kWh
Electricity Demand $157,644 22,524
kW-mo/yr
Electricity Fees $117,212 -
Natural Gas $311,638 53,531
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $25,375 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,362

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $658 $50 $414
18,096
kWh
$244
-
kW-mo/yr
- -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,295 $1,101 $2,077
90,720
kWh
$1,218
-
kW-mo/yr
- -
03 2.2437: Recover waste heat from equipment $3,008 $540 - - $3,008
-
MMBtu
-
04 2.4133: Use most efficient type of electric motors $1,524 $1,430 $960
41,935
kWh
$564
-
kW-mo/yr
- -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $3,060 $3,135 $1,927
84,152
kWh
$1,133
-
kW-mo/yr
- -
06 2.1233: Analyze flue gas for proper air/fuel ratio $3,825 $1,000 - - $3,825
-
MMBtu
-
07 3.1191: Change procedures / equipment / operating conditions $10,005 $75,600 - - $6,005
-
MMBtu
$4,000
TOTAL RECOMMENDED $25,375 $82,856 $5,379
234,903
kWh
$3,159
-
kW-mo/yr
$12,838
-
MMBtu
$4,000
TOTAL IMPLEMENTED $12,362 $6,716 $5,379
234,903
kWh
$3,159
-
kW-mo/yr
$3,825
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs