| Assessment Year | 2000 |
|---|---|
| Principal Product | processed meat products |
| NAICS |
n/a
|
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $50 M to 100M |
| # of Employees | 275 |
| Plant Area |
100,000
ft2
|
| Annual Production | 39,650
ton
|
| Production Hrs. Annual | 5,304
hrs
|
| Location (State) | Minnesota |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $444,064 | 12,714,830 |
kWh
|
$0.035 |
| Electricity Demand | $277,571 | 26,760 |
kW-mo/yr
|
$10.37 |
| Natural Gas | $32,374 | 7,275 |
MMBtu
|
$4.45 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,459 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $12,818 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,434 | $13,248 |
$5,739
164,420
kWh
|
$2,695
-
kW-mo/yr
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $3,780 | - |
$2,329
66,823
kWh
|
$1,451
-
kW-mo/yr
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $641 | - |
$413
11,723
kWh
|
$228
-
kW-mo/yr
|
|
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $604 | $125 |
$368
10,551
kWh
|
$236
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $13,459 | $13,373 |
$8,849
253,517
kWh
|
$4,610
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $12,818 | $13,373 |
$8,436
241,794
kWh
|
$4,382
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs