Assessment Year 1999
Principal Product labels
NAICS
n/a
SIC 2759: Commercial Printing, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 119
Plant Area 112,683
ft2
Annual Production 20,000
thousand feet
Production Hrs. Annual 5,000
hrs
Location (State) Nebraska

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $107,889 4,235,932
kWh
Electricity Demand $91,987 13,140
kW-mo/yr
Natural Gas $16,457 4,825
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $77,324 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,333 $113 $688
27,843
kWh
$5,645
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $4,966 $23,033 $2,925
117,819
kWh
$2,041
-
kW-mo/yr
- -
03 2.7111: Reduce illumination to minimum necessary levels $5,948 $4,194 $3,546
471,278
kWh
$2,402
-
kW-mo/yr
- -
04 2.7135: Install occupancy sensors $1,489 $2,328 $1,489
60,082
kWh
- - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $624 $215 $372
14,947
kWh
$252
-
kW-mo/yr
- -
06 3.1194: Use automatic flow control $57,964 $70,000 $4,390
177,022
kWh
$2,974
-
kW-mo/yr
$16,200 $34,400
TOTAL RECOMMENDED $77,324 $99,883 $13,410
868,991
kWh
$13,314
-
kW-mo/yr
$16,200 $34,400
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Personnel Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs