ITAC Assessment: IA0231
ITAC logo
ITAC Assessment: IA0231
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product tanned leather hides
NAICS
n/a
SIC 3111: Leather Tanning and Finishing
Sales Range $10
M
to 50
M
# of Employees 210
Plant Area 125,000
ft2
Annual Production 20,000
pieces
Production Hrs. Annual 6,468
hrs
Location (State) Iowa

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $277,000 12,586,753
kWh
Electricity Demand $195,500 24,192
kW-mo/yr
Natural Gas $413,400 103,097
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $43,940 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,567

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,069 - $2,433
110,492
kWh
$1,636
-
kW-mo/yr
- -
02 2.7142: Utilize higher efficiency lamps and/or ballasts $856 $3,093 $512
23,154
kWh
$344
-
kW-mo/yr
- -
03 2.7135: Install occupancy sensors $278 $466 $278
12,603
kWh
- - -
04 2.4231: Reduce the pressure of compressed air to the minimum required $2,516 $100 $1,540
70,047
kWh
$976
-
kW-mo/yr
- -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,567 $169 $936
42,497
kWh
$631
-
kW-mo/yr
- -
06 2.4221: Install compressor air intakes in coolest locations $791 $300 $471
21,395
kWh
$320
-
kW-mo/yr
- -
07 2.4133: Use most efficient type of electric motors $8,048 - $4,929
224,209
kWh
$3,119
-
kW-mo/yr
- -
08 2.1233: Analyze flue gas for proper air/fuel ratio $4,439 $2,000 - - $4,439
-
MMBtu
-
09 2.1213: Direct warmest air to combustion intake $1,231 $800 - - $1,231
-
MMBtu
-
10 4.425: Eliminate/reduce redundant inspections $20,145 $500 - - - $20,145
TOTAL RECOMMENDED $43,940 $7,428 $11,099
504,397
kWh
$7,026
-
kW-mo/yr
$5,670
-
MMBtu
$20,145
TOTAL IMPLEMENTED $1,567 $169 $936
42,497
kWh
$631
-
kW-mo/yr
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs