| Assessment Year | 1998 |
|---|---|
| Principal Product | bottled salad dressings |
| NAICS |
n/a
|
| SIC | 2035: Pickled Fruits and Vegetables, Vegetable Sauces and Seasonings, and Salad Dressings |
| Sales Range | $10 M to 50M |
| # of Employees | 60 |
| Plant Area |
43,000
ft2
|
| Annual Production | 28,000,000
lb
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $62,760 | 1,179,953 |
kWh
|
$0.053 |
| Natural Gas | $33,562 | 8,513 |
MMBtu
|
$3.94 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $431,377 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,625 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,251 | $340 |
$1,251
23,447
kWh
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $1,022 | $2,256 |
$1,022
19,343
kWh
|
- | - | |
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $524 | $1,100 |
$524
9,965
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $179 | $503 |
$179
3,517
kWh
|
- | - | |
| 05 | 2.7135: Install occupancy sensors | $173 | $133 |
$173
3,224
kWh
|
- | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $140 | $25 |
$140
2,638
kWh
|
- | - | |
| 07 | 3.5317: Sell / offer by-product as animal feed | $17,160 | $250 | - | - | $17,160 | |
| 08 | 4.441: Install automatic packing equipment | $186,435 | $208,600 |
$(-765.0)
(-14,361)
kWh
|
$187,200 | - | |
| 09 | 4.441: Install automatic packing equipment | $154,293 | $149,500 |
$(-1,707.0)
(-31,946)
kWh
|
$156,000 | - | |
| 10 | 4.441: Install automatic packing equipment | $70,200 | $180,000 | - | $70,200 | - | |
| TOTAL RECOMMENDED | $431,377 | $542,707 |
$817
15,827
kWh
|
$413,400 | $17,160 | ||
| TOTAL IMPLEMENTED | $2,625 | $3,232 |
$2,625
49,531
kWh
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Personnel Changes Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs