Assessment Year | 1995 |
---|---|
Principal Product | aluminum cans and ends |
NAICS |
n/a
|
SIC | 3411: Metal Cans |
Sales Range | $5 M to 10M |
# of Employees | 96 |
Plant Area |
105,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 8,520
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $313,032 | 6,840,563 |
kWh
|
$0.046 |
Natural Gas | $11,690 | 2,759 |
MMBtu
|
$4.24 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,897 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,689 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,304 | $79,400 |
$11,304
247,069
kWh
|
|
02 | 2.4133: Use most efficient type of electric motors | $12,241 | $1,577 |
$12,241
267,585
kWh
|
|
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,217 | $1,816 |
$4,217
92,321
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,911 | $520 |
$1,911
41,911
kWh
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,877 | $8,050 |
$2,877
63,013
kWh
|
|
06 | 2.7135: Install occupancy sensors | $203 | $539 |
$203
4,396
kWh
|
|
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $144 | $270 |
$144
3,224
kWh
|
|
TOTAL RECOMMENDED | $32,897 | $92,172 |
$32,897
719,519
kWh
|
||
TOTAL IMPLEMENTED | $23,689 | $81,247 |
$23,689
517,878
kWh
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings |