| Assessment Year | 1994 |
|---|---|
| Principal Product | automotive stampings |
| NAICS |
n/a
|
| SIC | 3465: Automotive Stampings |
| Sales Range | $10 M to 50M |
| # of Employees | 145 |
| Plant Area |
75,000
ft2
|
| Annual Production | 12,000
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $247,629 | 3,893,025 |
kWh
|
$0.064 |
| Natural Gas | $5,976 | 1,258 |
MMBtu
|
$4.75 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $22,571 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,280 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $10,255 | $315 |
$10,255
161,196
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,502 | $1,430 |
$4,502
70,047
kWh
|
- | |
| 03 | 2.7135: Install occupancy sensors | $2,191 | $1,224 |
$2,191
33,998
kWh
|
- | |
| 04 | 2.4133: Use most efficient type of electric motors | $2,523 | $10,378 |
$2,523
39,566
kWh
|
- | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,916 | $390 |
$4,279
67,409
kWh
|
$(-1,363.0)
-
MMBtu
|
|
| 06 | 2.2511: Insulate bare equipment | $184 | $68 |
$184
2,931
kWh
|
- | |
| TOTAL RECOMMENDED | $22,571 | $13,805 |
$23,934
375,147
kWh
|
$(-1,363.0)
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $17,280 | $12,123 |
$17,280
270,809
kWh
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs