Assessment Year | 1994 |
---|---|
Principal Product | pumps, steam traps, valves |
NAICS |
n/a
|
SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
110,000
ft2
|
Annual Production | 180,000
pieces
|
Production Hrs. Annual | 2,380
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,267 | 860,492 |
kWh
|
$0.084 |
Natural Gas | $53,535 | 14,611 |
MMBtu
|
$3.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,103 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,641 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $2,467 | $30 |
$2,467
29,308
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,121 | $400 |
$1,121
13,482
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,520 | $185 |
$1,520
18,171
kWh
|
|
04 | 2.7134: Use photocell controls | $554 | $275 |
$554
6,741
kWh
|
|
05 | 2.7135: Install occupancy sensors | $441 | $693 |
$441
5,275
kWh
|
|
TOTAL RECOMMENDED | $6,103 | $1,583 |
$6,103
72,977
kWh
|
||
TOTAL IMPLEMENTED | $2,641 | $585 |
$2,641
31,653
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs