Assessment Year | 1994 |
---|---|
Principal Product | centrifugal pumps |
NAICS |
n/a
|
SIC | 3594: Fluid Power Pumps and Motors |
Sales Range | $10 M to 50M |
# of Employees | 119 |
Plant Area |
95,300
ft2
|
Annual Production | 4,000
pieces
|
Production Hrs. Annual | 4,576
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $106,705 | 1,865,475 |
kWh
|
$0.057 |
Natural Gas | $12,408 | 2,920 |
MMBtu
|
$4.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,422 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $20,874 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7131: Add area lighting switches | $7,178 | $900 |
$7,178
125,733
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,127 | $1,227 |
$7,127
124,560
kWh
|
- | |
03 | 2.7122: Disconnect ballasts | $1,359 | $983 |
$1,359
23,740
kWh
|
- | |
04 | 2.7135: Install occupancy sensors | $1,226 | $2,371 |
$1,226
21,395
kWh
|
- | |
05 | 2.7224: Reduce space conditioning during non-working hours | $7,527 | - |
$7,527
131,594
kWh
|
- | |
06 | 2.7221: Lower temperature during the winter season and vice-versa | $3,695 | - | - |
$3,695
-
MMBtu
|
|
07 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $2,352 | $2,218 |
$3,487
60,961
kWh
|
$(-1,135.0)
-
MMBtu
|
|
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $669 | $25 |
$669
11,723
kWh
|
- | |
09 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $289 | - |
$195
3,517
kWh
|
$94
-
MMBtu
|
|
TOTAL RECOMMENDED | $31,422 | $7,724 |
$28,768
503,223
kWh
|
$2,654
-
MMBtu
|
||
TOTAL IMPLEMENTED | $20,874 | $5,481 |
$17,085
298,945
kWh
|
$3,789
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs