Assessment Year | 1993 |
---|---|
Principal Product | batteries |
NAICS |
n/a
|
SIC | 3692: Primary Batteries, Dry and Wet |
Sales Range | $10 M to 50M |
# of Employees | 320 |
Plant Area |
193,475
ft2
|
Annual Production | 241,000,000
pieces
|
Production Hrs. Annual | 4,288
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $467,736 | 11,917,937 |
kWh
|
$0.039 |
Natural Gas | $146,192 | 112,422 |
MMBtu
|
$1.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,223 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $8,636 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7314: Reduce ventilation air | $1,768 | $5,000 | - |
$1,768
-
MMBtu
|
|
02 | 2.7135: Install occupancy sensors | $6,868 | $4,490 |
$6,868
174,971
kWh
|
- | |
03 | 2.2492: Use "heat wheel" or other heat exchanger to cross-exchange building exhaust air with make-up air | $3,542 | $10,000 |
$3,515
89,683
kWh
|
$27
-
MMBtu
|
|
04 | 2.1213: Direct warmest air to combustion intake | $45 | $184 | - |
$45
-
MMBtu
|
|
TOTAL RECOMMENDED | $12,223 | $19,674 |
$10,383
264,654
kWh
|
$1,840
-
MMBtu
|
||
TOTAL IMPLEMENTED | $8,636 | $9,490 |
$6,868
174,971
kWh
|
$1,768
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs