Assessment Year | 1993 |
---|---|
Principal Product | publishing |
NAICS |
n/a
|
SIC | 2752: Commercial Printing, Lithographic |
Sales Range | $5 M to 10M |
# of Employees | 60 |
Plant Area |
20,000
ft2
|
Annual Production | 1,650
ton
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $55,169 | 754,689 |
kWh
|
$0.073 |
Natural Gas | $10,391 | 3,533 |
MMBtu
|
$2.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,175 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,116 | $2,000 |
$3,116
42,497
kWh
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $71 | $50 |
$71
879
kWh
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,414 | $441 |
$1,414
19,343
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $574 | $112 |
$574
7,913
kWh
|
|
05 | 2.7135: Install occupancy sensors | $265 | $414 |
$265
3,517
kWh
|
|
TOTAL RECOMMENDED | $5,440 | $3,017 |
$5,440
74,149
kWh
|
||
TOTAL IMPLEMENTED | $5,175 | $2,603 |
$5,175
70,632
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs