| Assessment Year | 1992 |
|---|---|
| Principal Product | HYDROSTATIC TRANSMISSION |
| NAICS |
n/a
|
| SIC | 3594: Fluid Power Pumps and Motors |
| Sales Range | $100 M to 500M |
| # of Employees | 450 |
| Plant Area |
n/a
|
| Annual Production | 162,000
pieces
|
| Production Hrs. Annual | 4,576
hrs
|
| Location (State) | Iowa |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $559,116 | 12,500,000 |
kWh
|
$0.045 |
| Natural Gas | $63,848 | 23,870 |
MMBtu
|
$2.67 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $10,137 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $6,285 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,833 | $551 |
$6,386
143,025
kWh
|
- | $(-553.0) | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $223 | $412 |
$303
6,741
kWh
|
- | $(-80.0) | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $607 | $1,000 |
$607
13,482
kWh
|
- | - | |
| 04 | 2.2437: Recover waste heat from equipment | $2,076 | $3,000 | - |
$2,076
-
MMBtu
|
- | |
| 05 | 2.4133: Use most efficient type of electric motors | $452 | $8,900 |
$452
10,258
kWh
|
- | - | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $946 | $2,192 |
$946
21,102
kWh
|
- | - | |
| TOTAL RECOMMENDED | $10,137 | $16,055 |
$8,694
194,608
kWh
|
$2,076
-
MMBtu
|
$(-633.0) | ||
| TOTAL IMPLEMENTED | $6,285 | $9,451 |
$6,838
153,283
kWh
|
- | $(-553.0) | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs