Assessment Year | 2000 |
---|---|
Principal Product | Plastic Bags |
NAICS |
n/a
|
SIC | 3081: Unsupported Plastics Film and Sheet |
Sales Range | $5 M to 10M |
# of Employees | 40 |
Plant Area |
30,000
ft2
|
Annual Production | 13,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $245,929 | 3,115,768 |
kWh
|
$0.079 |
Electricity Demand | $53,568 | 5,236 |
kW-mo/yr
|
$10.23 |
Electricity Fees | $(-26,525.0) | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $86,226 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,121 | $6,030 | n/a |
$5,197
65,944
kWh
|
$924
-
kW-mo/yr
|
- | - | - |
02 | 2.7135: Install occupancy sensors | $725 | $200 | n/a |
$725
9,086
kWh
|
- | - | - | - |
03 | 2.4133: Use most efficient type of electric motors | $5,922 | $15,200 | n/a |
$5,922
75,029
kWh
|
- | - | - | - |
04 | 2.2511: Insulate bare equipment | $8,538 | $1,008 | n/a |
$8,538
108,148
kWh
|
- | - | - | - |
05 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $60,015 | $400,000 | n/a | - |
$276,861
-
kW-mo/yr
|
$(-216,846.0)
-
MMBtu
|
- | - |
06 | 4.424: Improve space comfort conditioning | $4,365 | $500 | n/a | - | - | - | - | $4,365 |
07 | 3.5313: Increase amount of waste recovered for resale | $540 | $100 | n/a | - | - | - |
$540
-
lb
|
- |
TOTAL RECOMMENDED | $86,226 | $423,038 |
$20,382
258,207
kWh
|
$277,785
-
kW-mo/yr
|
$(-216,846.0)
-
MMBtu
|
$540
-
lb
|
$4,365 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs