| Assessment Year | 1999 |
|---|---|
| Principal Product | Metal Stampings |
| NAICS |
n/a
|
| SIC | 3469: Metal Stampings, Not Elsewhere Classified |
| Sales Range | $1 M to 5M |
| # of Employees | 68 |
| Plant Area |
95,000
ft2
|
| Annual Production | 100,000
lb
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $71,502 | 828,253 |
kWh
|
$0.086 |
| Electricity Demand | $48,195 | 5,333 |
kW-mo/yr
|
$9.04 |
| Electricity Fees | $1,905 | - |
|
- |
| Natural Gas | $45,359 | 7,076 |
MMBtu
|
$6.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $36,469 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,352 | $47,121 | n/a |
$9,650
111,665
kWh
|
$5,702
-
kW-mo/yr
|
- | - |
| 02 | 2.7135: Install occupancy sensors | $2,578 | $1,600 | n/a |
$2,578
29,894
kWh
|
- | - | - |
| 03 | 2.7135: Install occupancy sensors | $1,190 | $800 | n/a |
$1,190
13,775
kWh
|
- | - | - |
| 04 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $610 | - | n/a |
$610
7,034
kWh
|
- | - | - |
| 05 | 2.4131: Size electric motors for peak operating efficiency | $205 | $500 | n/a |
$205
2,345
kWh
|
- | - | - |
| 06 | 4.512: Condense operation into one building | $3,938 | $8,000 | n/a |
$2,474
28,722
kWh
|
$1,464
-
kW-mo/yr
|
- | - |
| 07 | 2.2223: Enhance sensitivity of temperature control and cutoff | $4,536 | $700 | n/a | - | - |
$4,536
-
MMBtu
|
- |
| 08 | 4.611: Begin a practice of predictive / preventative maintenance | $2,340 | $630 | n/a | - | - | - | $2,340 |
| 09 | 4.632: Change operating conditions | $5,720 | $27,500 | n/a | - | - | - | $5,720 |
| TOTAL RECOMMENDED | $36,469 | $86,851 |
$16,707
193,435
kWh
|
$7,166
-
kW-mo/yr
|
$4,536
-
MMBtu
|
$8,060 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs