Assessment Year | 1998 |
---|---|
Principal Product | Quartzware glass products |
NAICS |
n/a
|
SIC | 3641: Electric Lamp Bulbs and Tubes |
Sales Range | $5 M to 10M |
# of Employees | 20 |
Plant Area |
75,000
ft2
|
Annual Production | 3
thousand feet
|
Production Hrs. Annual | 2,295
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $8,742 | 92,028 |
kWh
|
$0.095 |
Electricity Demand | $5,654 | 727 |
kW-mo/yr
|
$7.78 |
Electricity Fees | $176 | - |
|
- |
Natural Gas | $1,183 | 147 |
MMBtu
|
$8.05 |
Other Gas | $74,046 | 1,421 |
MMBtu
|
$52.11 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,298 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,004 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1331: Burn a less expensive grade of fuel | $3,722 | - | - | - | - |
$3,722
-
MMBtu
|
- | |
02 | 2.1332: Convert combustion equipment to burn natural gas | $1,852 | - | - | - |
$(-1,852.0)
-
MMBtu
|
$3,704
-
MMBtu
|
- | |
03 | 4.514: Re-arrange equipment layout to reduce handling costs | $2,004 | $1,000 |
$91
879
kWh
|
$47
-
kW-mo/yr
|
- | - | $1,866 | |
04 | 4.513: Re-arrange equipment layout to reduce labor costs | $36,720 | $30,000 | - | - | - | - | $36,720 | |
TOTAL RECOMMENDED | $44,298 | $31,000 |
$91
879
kWh
|
$47
-
kW-mo/yr
|
$(-1,852.0)
-
MMBtu
|
$7,426
-
MMBtu
|
$38,586 | ||
TOTAL IMPLEMENTED | $2,004 | $1,000 |
$91
879
kWh
|
$47
-
kW-mo/yr
|
- | - | $1,866 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs