| Assessment Year | 1998 |
|---|---|
| Principal Product | Paper board packages |
| NAICS |
n/a
|
| SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
| Sales Range | $10 M to 50M |
| # of Employees | 165 |
| Plant Area |
105,000
ft2
|
| Annual Production | 6,375
ton
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | New Jersey |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $191,868 | 2,288,394 |
kWh
|
$0.084 |
| Electricity Demand | $65,254 | 16,915 |
kW-mo/yr
|
$3.86 |
| Electricity Fees | $(-26,501.0) | - |
|
- |
| Natural Gas | $87,661 | 9,917 |
MMBtu
|
$8.84 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $51,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,326 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7134: Use photocell controls | $950 | $3,600 |
$950
11,430
kWh
|
- | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,782 | $3,731 |
$1,782
21,395
kWh
|
- | - | - | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $2,131 | $1,493 |
$2,131
25,498
kWh
|
- | - | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $622 | $1,400 |
$570
6,741
kWh
|
$52
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.2136: Install / repair insulation on steam lines | $4,874 | $2,420 | - | - |
$4,874
-
MMBtu
|
- | - | |
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $18,070 | $5,550 | - | - |
$18,070
-
MMBtu
|
- | - | |
| 07 | 4.441: Install automatic packing equipment | $20,000 | $35,000 | - | - | - | $20,000 | - | |
| 08 | 4.514: Re-arrange equipment layout to reduce handling costs | $2,880 | $200 | - | - | - | $2,880 | - | |
| 09 | 3.4151: Minimize water usage | $338 | $900 | - | - | - | - |
$338
-
Tgal
|
|
| TOTAL RECOMMENDED | $51,647 | $54,294 |
$5,433
65,064
kWh
|
$52
-
kW-mo/yr
|
$22,944
-
MMBtu
|
$22,880 |
$338
-
Tgal
|
||
| TOTAL IMPLEMENTED | $9,326 | $7,620 |
$1,520
18,171
kWh
|
$52
-
kW-mo/yr
|
$4,874
-
MMBtu
|
$2,880 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs