| Assessment Year | 1998 |
|---|---|
| Principal Product | pretzels |
| NAICS |
n/a
|
| SIC | 2052: Cookies and Crackers |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
125,000
ft2
|
| Annual Production | 60,000,000
lb
|
| Production Hrs. Annual | 5,880
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $377,158 | 7,450,469 |
kWh
|
$0.051 |
| Electricity Demand | $84,930 | 13,188 |
kW-mo/yr
|
$6.44 |
| Electricity Fees | $(-26,939.0) | - |
|
- |
| Natural Gas | $1,152,353 | 272,412 |
MMBtu
|
$4.23 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $157,217 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $84,819 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,566 | $25,636 |
$6,248
122,802
kWh
|
$2,318
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $6,519 | $9,190 |
$6,519
128,664
kWh
|
- | - | - | - | |
| 03 | 2.7243: Improve air circulation with destratification fans / other methods | $12,311 | $1,200 | - | - |
$12,311
-
MMBtu
|
- | - | |
| 04 | 2.2414: Use waste heat from hot flue gases to preheat | $36,268 | $18,500 | - | - |
$36,268
-
MMBtu
|
- | - | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $24,394 | $13,600 |
$36,724
729,484
kWh
|
- |
$(-12,330.0)
-
MMBtu
|
- | - | |
| 06 | 4.515: Install shelves / racks to utilize unused space | $26,460 | $103,176 | - | - | - | - | $26,460 | |
| 07 | 4.441: Install automatic packing equipment | $26,460 | $30,270 | - | - | - | - | $26,460 | |
| 08 | 3.1192: Reduce scrap production | $15,135 | $200 | - | - | - |
$15,135
-
lb
|
- | |
| 09 | 3.7141: Improve cleaning efficiency by maintaining cleaning system | $1,104 | $535 | - | - | - | - | $1,104 | |
| TOTAL RECOMMENDED | $157,217 | $202,307 |
$49,491
980,950
kWh
|
$2,318
-
kW-mo/yr
|
$36,249
-
MMBtu
|
$15,135
-
lb
|
$54,024 | ||
| TOTAL IMPLEMENTED | $84,819 | $127,366 |
$43,243
858,148
kWh
|
- |
$(-19.0)
-
MMBtu
|
$15,135
-
lb
|
$26,460 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs