ITAC Assessment: HO0175
ITAC logo
ITAC Assessment: HO0175
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1999
Principal Product Thermoformed plastic packaging
NAICS
n/a
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $5
M
to 10
M
# of Employees 55
Plant Area 80,000
ft2
Annual Production 1,000,000
lb
Production Hrs. Annual 3,000
hrs
Location (State) New York

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $60,877 1,057,151
kWh
Electricity Demand $140,545 6,032
kW-mo/yr
Electricity Fees $9,168 -
Natural Gas $211 11
MMBtu
Fuel Oil #2 $24,096 3,988
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,959 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,639

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $4,263 $16,755 $1,479
24,326
kWh
$2,784
-
kW-mo/yr
-
02 2.2511: Insulate bare equipment $3,201 $168 $937
16,413
kWh
$2,264
-
kW-mo/yr
-
03 2.2437: Recover waste heat from equipment $320 $500 $320
5,569
kWh
- -
04 2.2511: Insulate bare equipment $800 $300 $800
13,775
kWh
- -
05 4.431: Train operators for maximum operating efficiency $9,375 - - - $9,375
06 4.521: Clear and rent existing space $18,000 $3,000 - - $18,000
TOTAL RECOMMENDED $35,959 $20,723 $3,536
60,083
kWh
$5,048
-
kW-mo/yr
$27,375
TOTAL IMPLEMENTED $35,639 $20,223 $3,216
54,514
kWh
$5,048
-
kW-mo/yr
$27,375
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs