ITAC Assessment: HO0164
ITAC logo
ITAC Assessment: HO0164
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product Steel Wire
NAICS
n/a
SIC 3125:
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area 160,000
ft2
Annual Production 46,000,000
lb
Production Hrs. Annual 7,488
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $322,529 3,939,625
kWh
Electricity Demand $83,419 9,096
kW-mo/yr
Electricity Fees $(-48,545.0) -
Natural Gas $301,790 74,600
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $110,085 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $93,037

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Solid Waste (haz) Savings
01 2.4133: Use most efficient type of electric motors $5,670 $3,625 $5,670
69,168
kWh
- - - -
02 2.2414: Use waste heat from hot flue gases to preheat $4,929 $3,099 - - $4,929
-
MMBtu
- -
03 2.2414: Use waste heat from hot flue gases to preheat $4,049 $722 - - $4,049
-
MMBtu
- -
04 3.1175: Use a different or recycled raw material $90,449 $10,000 - - - $90,449
-
gal
-
05 2.7111: Reduce illumination to minimum necessary levels $2,588 $200 $2,197
26,964
kWh
$391
-
kW-mo/yr
- - -
06 3.3131: Use evaporation to concentrate material $2,400 $5,000 - - - - $2,400
-
lb
TOTAL RECOMMENDED $110,085 $22,646 $7,867
96,132
kWh
$391
-
kW-mo/yr
$8,978
-
MMBtu
$90,449
-
gal
$2,400
-
lb
TOTAL IMPLEMENTED $93,037 $10,200 $2,197
26,964
kWh
$391
-
kW-mo/yr
- $90,449
-
gal
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Liquid (haz) Savings Solid Waste (haz) Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs