Assessment Year | 1997 |
---|---|
Principal Product | Steel Wire |
NAICS |
n/a
|
SIC | 3125: |
Sales Range | $10 M to 50M |
# of Employees | 65 |
Plant Area |
160,000
ft2
|
Annual Production | 46,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $322,529 | 3,939,625 |
kWh
|
$0.082 |
Electricity Demand | $83,419 | 9,096 |
kW-mo/yr
|
$9.17 |
Electricity Fees | $(-48,545.0) | - |
|
- |
Natural Gas | $301,790 | 74,600 |
MMBtu
|
$4.05 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $110,085 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $93,037 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $5,670 | $3,625 |
$5,670
69,168
kWh
|
- | - | - | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $4,929 | $3,099 | - | - |
$4,929
-
MMBtu
|
- | - | |
03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,049 | $722 | - | - |
$4,049
-
MMBtu
|
- | - | |
04 | 3.1175: Use a different or recycled raw material | $90,449 | $10,000 | - | - | - |
$90,449
-
gal
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $2,588 | $200 |
$2,197
26,964
kWh
|
$391
-
kW-mo/yr
|
- | - | - | |
06 | 3.3131: Use evaporation to concentrate material | $2,400 | $5,000 | - | - | - | - |
$2,400
-
lb
|
|
TOTAL RECOMMENDED | $110,085 | $22,646 |
$7,867
96,132
kWh
|
$391
-
kW-mo/yr
|
$8,978
-
MMBtu
|
$90,449
-
gal
|
$2,400
-
lb
|
||
TOTAL IMPLEMENTED | $93,037 | $10,200 |
$2,197
26,964
kWh
|
$391
-
kW-mo/yr
|
- |
$90,449
-
gal
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs