Assessment Year | 1996 |
---|---|
Principal Product | Business and Insurance Forms |
NAICS |
n/a
|
SIC | 2761: Manifold Business Forms |
Sales Range | $10 M to 50M |
# of Employees | 115 |
Plant Area |
120,000
ft2
|
Annual Production | 72,000,000
pieces
|
Production Hrs. Annual | 4,165
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $31,366 | 494,725 |
kWh
|
$0.063 |
Electricity Demand | $52,405 | 2,273 |
kW-mo/yr
|
$23.06 |
Electricity Fees | $6,401 | - |
|
- |
Natural Gas | $2,565 | 244 |
MMBtu
|
$10.51 |
Fuel Oil #6 | $35,024 | 6,884 |
MMBtu
|
$5.09 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $361,231 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,309 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,200 | $11,954 |
$4,496
70,926
kWh
|
$4,704
-
kW-mo/yr
|
- | - | |
02 | 2.4133: Use most efficient type of electric motors | $89 | $75 |
$89
1,465
kWh
|
- | - | - | |
03 | 2.7135: Install occupancy sensors | $388 | $1,000 |
$388
6,155
kWh
|
- | - | - | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $9,585 | $1,502 |
$9,585
267,292
kWh
|
- | - | - | |
05 | 2.2437: Recover waste heat from equipment | $660 | $628 | - | - |
$660
-
MMBtu
|
- | |
06 | 3.1192: Reduce scrap production | $340,000 | - | - | - | - |
$340,000
-
lb
|
|
07 | 4.511: Expand operations into unused space | $1,309 | $20,000 |
$630
9,965
kWh
|
$679
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $361,231 | $35,159 |
$15,188
355,803
kWh
|
$5,383
-
kW-mo/yr
|
$660
-
MMBtu
|
$340,000
-
lb
|
||
TOTAL IMPLEMENTED | $1,309 | $20,000 |
$630
9,965
kWh
|
$679
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Fuel Oil #6 Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs