Assessment Year | 1996 |
---|---|
Principal Product | Artificial Joints |
NAICS |
n/a
|
SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
Sales Range | $50 M to 100M |
# of Employees | 480 |
Plant Area |
200,000
ft2
|
Annual Production | 130,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $848,324 | 11,923,212 |
kWh
|
$0.071 |
Electricity Demand | $138,863 | 22,470 |
kW-mo/yr
|
$6.18 |
Natural Gas | $32,856 | 5,134 |
MMBtu
|
$6.40 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $118,185 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $962 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $43,564 | $111,891 |
$33,130
466,589
kWh
|
$10,434
-
kW-mo/yr
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,164 | $1,621 |
$1,040
14,654
kWh
|
$124
-
kW-mo/yr
|
- | - | |
03 | 2.7135: Install occupancy sensors | $493 | $400 |
$493
7,034
kWh
|
- | - | - | |
04 | 2.4133: Use most efficient type of electric motors | $962 | $1,650 |
$962
12,016
kWh
|
- | - | - | |
05 | 2.2414: Use waste heat from hot flue gases to preheat | $16,870 | $1,110 | - | - |
$16,870
-
MMBtu
|
- | |
06 | 2.6242: Minimize operation of equipment maintained in standby condition | $3,707 | - | - |
$3,707
-
kW-mo/yr
|
- | - | |
07 | 4.213: Purchase material from supplier in customized packaging | $51,425 | - | - | - | - |
$51,425
-
lb
|
|
TOTAL RECOMMENDED | $118,185 | $116,672 |
$35,625
500,293
kWh
|
$14,265
-
kW-mo/yr
|
$16,870
-
MMBtu
|
$51,425
-
lb
|
||
TOTAL IMPLEMENTED | $962 | $1,650 |
$962