| Assessment Year | 1996 |
|---|---|
| Principal Product | Pretzels |
| NAICS |
n/a
|
| SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
| Sales Range | $1 M to 5M |
| # of Employees | 60 |
| Plant Area |
25,000
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | New York |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $17,485 | 296,893 |
kWh
|
$0.059 |
| Electricity Demand | $41,077 | 1,764 |
kW-mo/yr
|
$23.29 |
| Electricity Fees | $3,134 | - |
|
- |
| Natural Gas | $67,371 | 8,144 |
MMBtu
|
$8.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,545 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,165 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $574 | $827 |
$228
3,810
kWh
|
$346
-
kW-mo/yr
|
- | - | |
| 02 | 2.4133: Use most efficient type of electric motors | $391 | $528 |
$155
2,638
kWh
|
$236
-
kW-mo/yr
|
- | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $2,380 | $740 | - | - |
$2,380
-
MMBtu
|
- | |
| 04 | 2.1131: Repair faulty insulation in furnaces, boilers, etc | $1,000 | $1,900 | - | - |
$1,000
-
MMBtu
|
- | |
| 05 | 3.6192: Use a less expensive method of waste removal | $1,200 | $100 | - | - | - |
$1,200
-
lb
|
|
| TOTAL RECOMMENDED | $5,545 | $4,095 |
$383
6,448
kWh
|
$582
-
kW-mo/yr
|
$3,380
-
MMBtu
|
$1,200
-
lb
|
||
| TOTAL IMPLEMENTED | $3,165 | $3,355 |
$383
6,448
kWh
|
$582
-
kW-mo/yr
|
$1,000
-
MMBtu
|
$1,200
-
lb
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs