Assessment Year | 1995 |
---|---|
Principal Product | Car Parts Kits |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
75,000
ft2
|
Annual Production | 15,000,000
pieces
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $32,926 | 275,791 |
kWh
|
$0.12 |
Natural Gas | $18,496 | 2,082 |
MMBtu
|
$8.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $4,173 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,122 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,051 | $11,011 |
$3,051
25,791
kWh
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $51 | $150 |
$51
586
kWh
|
- | |
03 | 2.6218: Turn off equipment when not in use | $357 | - |
$357
2,931
kWh
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $714 | $2,400 | - |
$714
-
MMBtu
|
|
TOTAL RECOMMENDED | $4,173 | $13,561 |
$3,459
29,308
kWh
|
$714
-
MMBtu
|
||
TOTAL IMPLEMENTED | $4,122 | $13,411 |
$3,408
28,722
kWh
|
$714
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs