Assessment Year | 1995 |
---|---|
Principal Product | Steel Shelving |
NAICS |
n/a
|
SIC | 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood |
Sales Range | $1 M to 5M |
# of Employees | 10 |
Plant Area |
24,000
ft2
|
Annual Production | 1,400,000
lb
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $27,703 | 107,562 |
kWh
|
$0.26 |
Natural Gas | $15,167 | 1,540 |
MMBtu
|
$9.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,997 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,315 | $893 |
$2,315
9,086
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $521 | $416 |
$521
2,052
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $104 | $193 |
$104
586
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $478 | $750 |
$478
1,758
kWh
|
- | - | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $5,745 | $12,500 |
$8,079
13,482
kWh
|
$(-2,634.0)
-
MMBtu
|
$300 | |
06 | 2.6218: Turn off equipment when not in use | $834 | $1,500 |
$834
13,189
kWh
|
- | - | |
TOTAL RECOMMENDED | $9,997 | $16,252 |
$12,331
40,153
kWh
|
$(-2,634.0)
-
MMBtu
|
$300 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs