Assessment Year | 1994 |
---|---|
Principal Product | Rolled Sheet Metal |
NAICS |
n/a
|
SIC | 3316: Cold-Rolled Steel Sheet, Strip, and Bars |
Sales Range | $50 M to 100M |
# of Employees | 75 |
Plant Area |
75,000
ft2
|
Annual Production | 25,000,000
lb
|
Production Hrs. Annual | 8,280
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $440,491 | 8,218,933 |
kWh
|
$0.054 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,323 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $938 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $650 | $1,279 |
$650
12,016
kWh
|
|
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $288 | $567 |
$288
5,275
kWh
|
|
03 | 2.4133: Use most efficient type of electric motors | $385 | $410 |
$385
7,034
kWh
|
|
TOTAL RECOMMENDED | $1,323 | $2,256 |
$1,323
24,325
kWh
|
||
TOTAL IMPLEMENTED | $938 | $1,846 |
$938
17,291
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs