| Assessment Year | 1993 |
|---|---|
| Principal Product | Steel Shelves and lockers |
| NAICS |
n/a
|
| SIC | 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood |
| Sales Range | $10 M to 50M |
| # of Employees | 350 |
| Plant Area |
250,000
ft2
|
| Annual Production | 20,000
ton
|
| Production Hrs. Annual | 4,888
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $416,077 | 4,564,771 |
kWh
|
$0.091 |
| Natural Gas | $160,172 | 46,505 |
MMBtu
|
$3.44 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $190,345 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,210 | $3,334 |
$3,210
35,170
kWh
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,051 | $3,337 |
$1,051
11,430
kWh
|
- | - | |
| 03 | 2.4133: Use most efficient type of electric motors | $740 | $1,134 |
$740
8,206
kWh
|
- | - | |
| 04 | 2.2511: Insulate bare equipment | $130 | $112 | - |
$130
-
MMBtu
|
- | |
| 05 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $185,214 | $900,000 |
$356,605
3,911,489
kWh
|
$(-85,309.0)
-
MMBtu
|
$(-86,082.0) | |
| TOTAL RECOMMENDED | $190,345 | $907,917 |
$361,606
3,966,295
kWh
|
$(-85,179.0)
-
MMBtu
|
$(-86,082.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs