| Assessment Year | 1993 |
|---|---|
| Principal Product | Hand held spraying equipment |
| NAICS |
n/a
|
| SIC | 3563: Air and Gas Compressors |
| Sales Range | $5 M to 10M |
| # of Employees | 81 |
| Plant Area |
80,000
ft2
|
| Annual Production | 250,000
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $166,504 | 1,910,903 |
kWh
|
$0.087 |
| Natural Gas | $13,008 | 2,279 |
MMBtu
|
$5.71 |
| Fuel Oil #2 | $6,892 | 1,390 |
MMBtu
|
$4.96 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,407 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,449 | $2,027 |
$2,449
28,136
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,235 | $3,015 |
$1,235
14,068
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $537 | $1,436 |
$537
6,155
kWh
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,782 | $10,560 |
$3,782
43,376
kWh
|
- | |
| 05 | 2.2511: Insulate bare equipment | $404 | $600 | - |
$404
-
MMBtu
|
|
| TOTAL RECOMMENDED | $8,407 | $17,638 |
$8,003
91,735
kWh
|
$404
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs