Assessment Year | 1993 |
---|---|
Principal Product | Mechanical Control Systems |
NAICS |
n/a
|
SIC | 3315: Steel Wiredrawing and Steel Nails and Spikes |
Sales Range | $1 M to 5M |
# of Employees | 70 |
Plant Area |
45,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $56,281 | 397,714 |
kWh
|
$0.14 |
LPG | $4,785 | 407 |
MMBtu
|
$11.76 |
Fuel Oil #2 | $17,040 | 2,618 |
MMBtu
|
$6.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $10,541 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,541 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,748 | $2,605 |
$6,748
47,479
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,764 | $3,483 |
$1,764
12,603
kWh
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $319 | $285 |
$319
2,345
kWh
|
- | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $809 | $300 |
$809
5,569
kWh
|
- | |
05 | 2.2136: Install / repair insulation on steam lines | $67 | $204 | - |
$67
-
MMBtu
|
|
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $834 | $40 |
$834
5,862
kWh
|
- | |
TOTAL RECOMMENDED | $10,541 | $6,917 |
$10,474
73,858
kWh
|
$67
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,541 | $6,917 |
$10,474
73,858
kWh
|
$67
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Fuel Oil #2 Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs