Assessment Year | 1992 |
---|---|
Principal Product | SM. METAL STAMPINGS |
NAICS |
n/a
|
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 40 |
Plant Area |
n/a
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $62,788 | 461,899 |
kWh
|
$0.14 |
Natural Gas | $20,440 | 3,037 |
MMBtu
|
$6.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,523 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $322 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,907 | $2,910 |
$4,133
30,481
kWh
|
- | $(-226.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,989 | $1,400 |
$1,989
14,654
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $322 | $392 |
$322
2,345
kWh
|
- | - | |
04 | 2.2136: Install / repair insulation on steam lines | $305 | $325 | - |
$305
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $6,523 | $5,027 |
$6,444
47,480
kWh
|
$305
-
MMBtu
|
$(-226.0) | ||
TOTAL IMPLEMENTED | $322 | $392 |
$322
2,345
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs