Assessment Year | 1992 |
---|---|
Principal Product | VALVES |
NAICS |
n/a
|
SIC | 3491: Industrial Valves |
Sales Range | $5 M to 10M |
# of Employees | 180 |
Plant Area |
n/a
|
Annual Production | 400
pieces
|
Production Hrs. Annual | 8,544
hrs
|
Location (State) | New York |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $483,579 | 4,034,584 |
kWh
|
$0.12 |
Natural Gas | $29,398 | 4,505 |
MMBtu
|
$6.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $75,734 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,497 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Fuel Oil #2 Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,104 | $1,735 |
$1,204
9,965
kWh
|
- | $(-100.0) | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,154 | $5,700 |
$5,154
43,083
kWh
|
- | - | |
03 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $69,237 | $330,000 |
$107,902
901,524
kWh
|
$(-18,865.0)
-
MMBtu
|
$(-19,800.0) | |
04 | 2.4133: Use most efficient type of electric motors | $239 | $180 |
$239
2,052
kWh
|
- | - | |
TOTAL RECOMMENDED | $75,734 | $337,615 |
$114,499
956,624
kWh
|
$(-18,865.0)
-
MMBtu
|
$(-19,900.0) | ||
TOTAL IMPLEMENTED | $6,497 | $7,615 |
$6,597
55,100
kWh
|
- | $(-100.0) |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs