Assessment Year 2026
Principal Product Infinitely Recyclable Glass Containers
NAICS 327213: Glass Container Manufacturing
SIC 3221: Glass Containers
Sales Range $50
M
to 100
M
# of Employees 174
Plant Area 842,179
ft2
Annual Production 130,800
ton
Production Hrs. Annual 8,760
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $4,883,016 53,234,930
kWh
Electricity Fees $7,271 -
Natural Gas $3,590,801 713,008
MMBtu
TOTAL YEARLY COSTS $8,481,088
RECOMMENDED SAVINGS* $3,466,617 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.8114: Change rate schedules or other changes in utility service $74,736 $100 - - $74,736
02 2.4239: Eliminate or reduce compressed air usage $195,666 $4,000 $195,666
2,126,800
kWh
- -
03 2.7135: Install occupancy sensors $1,016 $2,763 $1,016
11,048
kWh
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $3,053 $10,420 $3,053
33,183
kWh
- -
05 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $1,944,968 $7,245,000 $2,417,760
26,280,000
kWh
$(-472,792.0)
-
MMBtu
-
06 2.9114: Use solar heat to make electricty $1,247,178 $8,987,283 $1,247,178
13,596,814
kWh
- -
TOTAL RECOMMENDED $3,466,617 $16,249,566 $3,864,673
42,047,845
kWh
$(-472,792.0)
-
MMBtu
$74,736
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs