Assessment Year 2026
Principal Product Automotive Exterior and Interior Parts
NAICS 336111: Automobile Manufacturing
SIC 3711: Motor Vehicles and Passenger Car Bodies
Sales Range $50
M
to 100
M
# of Employees 260
Plant Area 225,000
ft2
Annual Production 12,849,043
units
Production Hrs. Annual 6,240
hrs
Location (State) Georgia

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $1,374,086 15,278,497
kWh
Electricity Fees $6,917 -
Natural Gas $59,407 5,511
MMBtu
TOTAL YEARLY COSTS $1,440,410
RECOMMENDED SAVINGS* $540,122 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $18,456 $600 $18,456
205,070
kWh
- -
02 2.2625: Chill water to the highest temperature possible $6,481 $1,200 $6,481
72,013
kWh
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,959 $1,850 $6,859
76,212
kWh
- $(-2,900.0)
04 2.6211: Conserve energy by efficient use of vending machines $62 $135 $62
687
kWh
- -
05 2.4239: Eliminate or reduce compressed air usage $1,010 $2,400 $1,010
11,219
kWh
- -
06 2.6212: Turn off equipment during breaks, reduce operating time $396 $1,950 $396
4,404
kWh
- -
07 2.7243: Improve air circulation with destratification fans / other methods $4,198 $22,400 $4,198
46,644
kWh
- -
08 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat $41,860 $258,750 $73,125
812,500
kWh
$(-31,265.0)
-
MMBtu
-
09 2.9114: Use solar heat to make electricty $463,700 $3,319,567 $463,700
5,155,894
kWh
- -
TOTAL RECOMMENDED $540,122 $3,608,852 $574,287
6,384,643
kWh
$(-31,265.0)
-
MMBtu
$(-2,900.0)
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs