| Assessment Year | 2026 |
|---|---|
| Principal Product | Aerospace Manufactured Parts |
| NAICS | 332710: Machine Shops |
| SIC | 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 18 |
| Plant Area |
25,000
ft2
|
| Annual Production | 44,508
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $80,694 | 620,680 |
kWh
|
$0.13 |
| Electricity Fees | $6,496 | - |
|
- |
| LPG | $846 | 26 |
MMBtu
|
$32.54 |
| TOTAL YEARLY COSTS | $88,036 | |||
| RECOMMENDED SAVINGS* | $31,766 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8121: Apply for tax-free status for energy purchases | $5,503 | $200 | - | $5,503 | - | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,777 | $200 |
$2,777
21,365
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,904 | $1,850 |
$12,804
98,492
kWh
|
- | $(-2,900.0) | |
| 04 | 2.7132: Install timers on light switches in little used areas | $6,314 | $1,658 |
$6,314
48,571
kWh
|
- | - | |
| 05 | 2.7224: Reduce space conditioning during non-working hours | $2,779 | $750 |
$2,779
21,377
kWh
|
- | - | |
| 06 | 2.6211: Conserve energy by efficient use of vending machines | $86 | $45 |
$86
663
kWh
|
- | - | |
| 07 | 2.4239: Eliminate or reduce compressed air usage | $2,644 | $1,500 |
$2,644
20,338
kWh
|
- | - | |
| 08 | 2.6212: Turn off equipment during breaks, reduce operating time | $201 | $260 |
$201
1,546
kWh
|
- | - | |
| 09 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $1,558 | $5,400 |
$1,558
11,985
kWh
|
- | - | |
| TOTAL RECOMMENDED | $31,766 | $11,863 |
$29,163
224,337
kWh
|
$5,503 | $(-2,900.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Personnel Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs