| Assessment Year | 2024 |
|---|---|
| Principal Product | Dimensional Lumber |
| NAICS | 321113: Sawmills |
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $50 M to 100M |
| # of Employees | 161 |
| Plant Area |
95,010
ft2
|
| Annual Production | 123,529,000,000
units
|
| Production Hrs. Annual | 4,680
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,531,912 | 18,178,804 |
kWh
|
$0.084 |
| TOTAL YEARLY COSTS | $1,531,912 | |||
| RECOMMENDED SAVINGS* | $153,625 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $51,804 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $51,238 | $1,850 |
$54,138
644,503
kWh
|
$(-2,900.0) | |
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $566 | $1,625 |
$566
6,735
kWh
|
- | |
| 03 | 2.9114: Use solar heat to make electricty | $101,821 | $1,492,532 |
$101,821
1,208,279
kWh
|
- | |
| TOTAL RECOMMENDED | $153,625 | $1,496,007 |
$156,525
1,859,517
kWh
|
$(-2,900.0) | ||
| TOTAL IMPLEMENTED | $51,804 | $3,475 |
$54,704
651,238
kWh
|
$(-2,900.0) | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs